Method B - Post Emulsifiable, Lipophilic

PENETRANT
985P12
985P13
985P14
996


Dwell
5-45 Minutes

Lipophilic
Emulsiphier

9PR3
Dip & Drain*



Wash
50-100 F


Dry <160F

Developer
9D4A
9D1B
NQ1



Dwell
5-45 Minutes


Inspect

Developer
9D75
9D76


Dry
<160F

* Contact time during drain is critical control step.